POT-1
Pull off type opening force tester
Technical characteristics :
- Range: 50 / 200 / 1000 N (To be specified when ordering)
- Tension and compression measurement
- Reversible digital display
- Programming by menu.
- Continuous / Peak / PC connection measurement modes
- Zero recalibration
- Precision: 0.05 N (depending on range)
- Display and programming of thresholds
- Units: kgf. / Lbf / N
- Integrated battery
- Data transfer and curve
- Dimensions: 500 x 250 x 600 mm
- Weight: 15 KG
- Air inlet: 0 - 6 bar
Options:
Use :
- Install the hook in the capsule ring and the wire in the lower pulley.
- Activate the pneumatic valve using the handle to carry out the first “stretching” step. This step will be carried out at stable speed for better measurement.
- Change the wire to the upper pulley (this position is set at 45° but can be modified)
- Activate the pneumatic valve again using the handle to achieve the “stretch 2” second. This step will be carried out at stable speed for better measurement.
- Return the handle to the initial position to finish the test.
Description :
POT-1 was developed to allow testing on “pull off” capsules while respecting each step.
The POT-1 integrates a precision dynamometer and semi-automatic cycles for better test reproducibility. The angle of each step is adjustable. This device has been developed to allow testing on different bottle sizes.